Guangzhou chime-long hotel

Date:2010-10-24

Guangzhou chime-long hotel is a wild animal tourism scenic spot located in the ecological garden theme hotel. For domestic and international business guests has totally subtle imagine living, vacation, provide full service rooms and executive floors. Guest rooms are equipped with modern business service facilities, such as satellite TV, broadband Internet access, speech to voice mail, idd, etc. Guangzhou chime-long hotel scale, its are built up to 1,200 already planning phase, each guest room rooms have gazebo, minimal standard also has 50 square meters, and has a variety of types of rooms available for people to choose.

A, the user needs

1, the design objective and requirements

Mainly aimed at guangzhou chime-long hotel overall information, network and intelligent construction design, Wisconsin resistance for the hotel's integrated wiring provides resistance to neville dean six types of cabling system solutions. Unified pipeline, unified medium cable piping, wiring, in order to make this wiring system can be easily connected with terminal equipment, set up telephones, computers, television, surveillance TV conference network. Guangzhou chime-long hotel structure integrated wiring design goal is to establish a meet intelligent hotel system integration, network integration, and has advanced technology level of integrated computer network system, the system in terms of applicability, flexibility, modular, expansion of each function indexes such as future development completely satisfy demands, and so will ascend to chime-long hotel new highly personalized, intelligent, emerged as an intelligent digital hotel.

This scheme Lord wiring workshop (BD) using cable directly connected. For the distribution line between (FD) to six categories of line by information points port, the major wiring way part using fiber to the desktop wiring way. Specifically, this scheme solution of application and supports the following equipment:

speech

☆ program-controlled switch

☆ telephone, fax

☆ conference call

☆ voicemail, speech store information

data

The inside the building ☆ establishing LAN, connecting office computer, realize OA (office automation) system

☆ each floor, high-speed Ethernet LAN interconnection between

☆ Internet connection

Wisconsin resistance six categories of cabling system's has met the EIA/TIA 568 - b. 2, ISO11801 international standards zhanglongjiudian hotel, can make the wiring solutions disposable to meet future 15 to 30 years will appear network application requirements.

2, the project profile

Guangzhou chime-long hotel is a wild animal tourism scenic spot located in the ecological garden theme hotel. This scheme involving guangzhou chime-long hotel phase ii project, of which there are seven building for six floors house A1, A2, A3, A4 8 layers, A5 for 7 layer, conference center and large TangLou each for 3 layer and layer 4, with a total construction area of 166,489 square meters million square meters.

Second, technical scheme

This design scheme based on user needs and analysis, satisfying the wiring system advanced, flexibility and economy, wiring system engineering requirements in accordance with the following ways:

(1) complex backbone adopts 6 core multi-mode outdoor cable, net of ten thousand

(2) using three kinds of 50 to multi-cores cable, 100 of each layer of the building connected each of the management subsystem control-cabinet.

(3) the corrosion resistance of Wisconsin dean six of the standard four cabling system not shielded twisted-pair cable (UTP) as horizontal lines connected to each subsystem wiring functional areas of information points.

(4) the corrosion resistance of six kinds of standards Wisconsin dean of structured, modular components control-cabinet floors, each region of the distribution frames.

(5) the information points on the corrosion resistance six categories of information module Wisconsin dean and the allocation corresponding stand-up double, four mouth information panel.

(6) with a single phase during outdoor cable connected by;

(7) and according to need in total wiring workshop and room, in various specifications of network cabinets;

(8) in each building between the into line configuration signal lines surge protector the distribution frames, in order to meet the new gb GB50311, the GB50312 compellent items requirements (when cable from entering the building outside buildings, should choose fit of signal lines surge protector, signal lines surge protector should comply with the design requirements.

(9) integrated wiring system each subsystem (including: workspace subsystem, level subsystems, management subsystem, equipment room subsystem, vertical route system, the architectural complex subsystem and into line with the design are between) GB 50311-2007 "integrated wiring system engineering design in the code of each subsystem rules.

1, working subsystem

Workspace subsystem connected to the terminal equipment information socket connection and composed of information socket. The modularized product information socket on the corrosion resistance, all six categories of information module Wisconsin dean, use double mouth dustproof Wisconsin resistance's on the wall, all socket type socket panel all accord with ANSI/EIA/TIA - 568 standards.
 